NSN 5950-00-945-0650

Part Details | POWER TRANSFORMER

5950-00-945-0650 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.

Alternate Parts: 8201425001, 8201425-001, 73C828001, 73C828-001, 172059000, 172059-000, 73C828001, 73C828-001, 73C828001, 73C828-001, 5950-00-945-0650, 00-945-0650, 5950009450650, 009450650

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59FEB 18, 196600-945-065032496 ( TRANSFORMER, POWER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-00-945-0650
Part Number Cage Code Manufacturer
8201425-00104660AIL SYSTEMS INCSUB OF EATON CORP
73C828-00104660AIL SYSTEMS INCSUB OF EATON CORP
172059-00081413BAE SYSTEMS INFORMATION ANDELECTRONIC SYSTEMS INTEGRATION I
73C828-00190095PULSE ELECTRONICS CORPORATIONDBA PULSE COMPONENTS DIVISION
73C828-00172964ROBERT M HADLEY COMPANY INC
Technical Data | NSN 5950-00-945-0650
Characteristic Specifications
TERMINAL TYPE AND QUANTITY13 TURRET
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH3.609 INCHES MINIMUM AND 3.641 INCHES MAXIMUM
BODY WIDTH2.734 INCHES MINIMUM AND 2.766 INCHES MAXIMUM
OVERALL HEIGHT1.922 INCHES MINIMUM AND 1.954 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
TEST DATA DOCUMENT04660-73828 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
TRANSFORMER WINDING CONNECTION TYPE DELTA-WYE
MAXIMUM OPERATING TEMP170.0 DEG CELSIUS