NSN 5950-01-134-1344

Part Details | POWER TRANSFORMER

5950-01-134-1344 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.

Alternate Parts: 1448900001, 14489000-01, 1448900001, 14489000-01, 1448900001, 14489000-01, 67080380, 5950-01-134-1344, 01-134-1344, 5950011341344, 011341344

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUN 27, 198201-134-134432496 ( TRANSFORMER, POWER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-01-134-1344
Part Number Cage Code Manufacturer
14489000-0127963GENERAL DYNAMICS INFORMATION SYSTEMSINC.
14489000-0198330OECO, LLC
14489000-0190095PULSE ELECTRONICS CORPORATIONDBA PULSE COMPONENTS DIVISION
6708038080023VISHAY HIREL SYSTEMS LLCDIV MARSHALL
Technical Data | NSN 5950-01-134-1344
Characteristic Specifications
TERMINAL TYPE AND QUANTITY22 WIRE LEAD
INCLOSURE TYPE OPEN
BODY LENGTH6.000 INCHES MAXIMUM
BODY HEIGHT4.500 INCHES MAXIMUM
BODY WIDTH4.750 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
TRANSFORMER WINDING CONNECTION TYPE WYE-WYE
COOLING METHOD SELF-COOLED
INSTALLATION FOR WHICH DESIGNED INDOOR NONPORTABLE