NSN 5950-01-138-1881

Part Details | POWER TRANSFORMER

5950-01-138-1881 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.

Alternate Parts: 9058761, 905876-1, 13137, 03835, 9058761, 905876-1, 9058761, 905876-1, 5950-01-138-1881, 01-138-1881, 5950011381881, 011381881

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59SEP 08, 198201-138-188132496 ( TRANSFORMER, POWER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-01-138-1881
Part Number Cage Code Manufacturer
905876-125656DBP MICROWAVE INC.DBA
1313753854MAGNESPEC, INC.
0383515634MAGNETIKA, INC.
905876-106481NORTHROP GRUMMAN SYSTEMS CORPORATIONDIV NAVIGATION AND MARITIME SYSTEMS
905876-172964ROBERT M HADLEY COMPANY INC
Technical Data | NSN 5950-01-138-1881
Characteristic Specifications
TERMINAL TYPE AND QUANTITY25 TURRET
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH2.110 INCHES MINIMUM AND 2.130 INCHES MAXIMUM
BODY HEIGHT1.060 INCHES MAXIMUM
BODY WIDTH2.110 INCHES MINIMUM AND 2.130 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURESONE PRIMARY WINDING; EIGHT SECONDARY WINDINGS,FIRST,SECOND,THIRD,FOURTH,FIFTH,AND SIXTH SECONDARY CENTER TAPPED
MAXIMUM OPERATING TEMP130.0 DEG CELSIUS