NSN 5950-01-304-1353

Part Details | POWER TRANSFORMER

5950-01-304-1353 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.

Alternate Parts: AP17500388, AP1750/0388, ES602901, ES6029-01, ES602901, ES6029-01, 5950-01-304-1353, 01-304-1353, 5950013041353, 013041353

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59JUL 13, 198901-304-135332496 ( TRANSFORMER, POWER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-01-304-1353
Part Number Cage Code Manufacturer
AP1750/038824355ANALOG DEVICES, INC.DIV CORPORATE HEADQUARTERS
ES6029-0198255DRS SUSTAINMENT SYSTEMS, INC.
ES6029-0120418DRS SUSTAINMENT SYSTEMS, INC.Use CAGE Code 98255 for cataloging
Technical Data | NSN 5950-01-304-1353
Characteristic Specifications
TERMINAL TYPE AND QUANTITY9 PIN
INCLOSURE TYPE FULLY INCLOSED
BODY LENGTH2.235 INCHES MINIMUM AND 2.255 INCHES MAXIMUM
BODY HEIGHT0.380 INCHES MINIMUM AND 0.430 INCHES MAXIMUM
BODY WIDTH1.110 INCHES MINIMUM AND 1.135 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
TEST DATA DOCUMENT20418-ES6029 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
TRANSFORMER WINDING CONNECTION TYPE SCOTT
MAXIMUM OPERATING TEMP130.0 DEG CELSIUS
PRECIOUS MATERIAL GOLD
PRECIOUS MATERIAL AND LOCATIONTERMINAL SURFACES GOLD