NSN 5950-01-309-0045
Part Details | POWER TRANSFORMER
5950-01-309-0045 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.
Alternate Parts: 127231G1, 5950-01-309-0045, 01-309-0045, 5950013090045, 013090045
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | OCT 08, 1989 | 01-309-0045 | 32496 ( TRANSFORMER, POWER ) |
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-01-309-0045
Part Number | Cage Code | Manufacturer |
---|---|---|
127231G1 | 94271 | LOCKHEED MARTIN CORPORATIONDBA LOCKHEED MARTIN |
Technical Data | NSN 5950-01-309-0045
Characteristic | Specifications |
---|---|
TERMINAL TYPE AND QUANTITY | 11 SOLDER STUD |
SPECIAL FEATURES | INSULATION RESISTANCE GREATER THAN 10K MEG AT 500 VDC; XFORMER INSULATION RATING CLASS S 130 DEG C; CORE BOLTS SHALL BE INSULATED; DIELECTRIC WITHSTANDING VOLTAGE 1500 V RMS ALL WINDINGS TO CORE AND EA WINDING TO ALL OTHER WINDINGS AL 60 HZ FOR ONE MINUTE |
REFERENCE NUMBER DIFFERENTIATING CHARACTERISTICS | MATERIAL WILL BE IN ACCORDANCE WITH SHIPS PARTS CONTROL CENTER ACTIVITY HX QUALITY CONTROL,MANUFACTURING AND TESTING SPECIFICATIONS |
CRITICALITY CODE JUSTIFICATION | ZZZY |