NSN 5950-01-311-9275

Part Details | POWER TRANSFORMER

5950-01-311-9275 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.

Alternate Parts: 441101, 473120, PEI 8088, 5950-01-311-9275, 01-311-9275, 5950013119275, 013119275

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59DEC 06, 198901-311-927532496 ( TRANSFORMER, POWER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-01-311-9275
Part Number Cage Code Manufacturer
44110172149ELECTRONIC TRANSFORMER CORP.DIV ELECTRONIC TRANSFORMER
47312054418MILTOPE CORPORATION
PEI 808813483PRECISION ELECTRONICS, INC.
Technical Data | NSN 5950-01-311-9275
Characteristic Specifications
TERMINAL TYPE AND QUANTITY30 QUICK DISCONNECT, MALE
INCLOSURE TYPE FULLY INCLOSED
OVERALL LENGTH8.000 INCHES MAXIMUM
OVERALL HEIGHT5.620 INCHES MAXIMUM
OVERALL WIDTH5.500 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURES1PRIMARY WINDING; 8SECONDARY WINDINGS; ALL SECONDARY WINDINGS VOLTAGE AND CURRENTS RECTIFIED
TRANSFORMER WINDING CONNECTION TYPE DELTA-DELTA AND DELTA-WYE
MAXIMUM OPERATING TEMP50.0 DEG CELSIUS