NSN 5950-01-324-4292

Part Details | POWER TRANSFORMER

5950-01-324-4292 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.

Alternate Parts: 7269411, 726941-1, 1100067001, 11-00067-001, PEI 8844, 5950-01-324-4292, 01-324-4292, 5950013244292, 013244292

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59AUG 19, 199001-324-429232496 ( TRANSFORMER, POWER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-01-324-4292
Part Number Cage Code Manufacturer
726941-121562GENERAL DYNAMICS OTS (AEROSPACE),INC.
11-00067-00121562GENERAL DYNAMICS OTS (AEROSPACE),INC.
PEI 884413483PRECISION ELECTRONICS, INC.
Technical Data | NSN 5950-01-324-4292
Characteristic Specifications
TERMINAL TYPE AND QUANTITY4 WIRE LEAD AND 12 TAB, SOLDER LUG
INCLOSURE TYPE FULLY INCLOSED
BODY HEIGHT1.005 INCHES MINIMUM AND 1.025 INCHES MAXIMUM
OVERALL LENGTH1.830 INCHES MINIMUM AND 1.870 INCHES MAXIMUM
OVERALL WIDTH1.395 INCHES MINIMUM AND 1.415 INCHES MAXIMUM
RELIABILITY INDICATOR NOT ESTABLISHED
SPECIAL FEATURESONE PRIMARY WINDING; SIX SECONDARY WINDINGS WITH THE FIRST AND FIFTH SECONDARY WINDINGS TAPPED
TEST DATA DOCUMENT16340-11-00067 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAWING)
MAXIMUM OPERATING TEMP160.0 DEG CELSIUS
END ITEM IDENTIFICATION5805-01-188-3993 CENTRAL OFFICE,TELEPHONE,AUTOMATIC
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION FUNGUS RESISTANT AND CORROSION RESISTANT