NSN 5950-01-380-9780

Part Details | POWER TRANSFORMER

5950-01-380-9780 A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see TRANSFORMER (1), POWER, AUTOTRANSFORMER. Excludes TRANSFORMER (1), PULSE.

Alternate Parts: 5135801, 51-358-01, TF5135801, TF51-358-01, 5950-01-380-9780, 01-380-9780, 5950013809780, 013809780

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59OCT 04, 199301-380-978032496 ( TRANSFORMER, POWER )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5950-01-380-9780
Part Number Cage Code Manufacturer
51-358-0108748ELDEC CORPORATIONDBA CRANE AEROSPACE & ELECTRONICS
TF51-358-0108748ELDEC CORPORATIONDBA CRANE AEROSPACE & ELECTRONICS
Technical Data | NSN 5950-01-380-9780
Characteristic Specifications
TERMINAL TYPE AND QUANTITY9 WIRE LEAD
INCLOSURE TYPE FULLY INCLOSED
BODY WIDTH3.600 INCHES MAXIMUM
OVERALL LENGTH5.460 INCHES MAXIMUM
OVERALL HEIGHT6.100 INCHES MAXIMUM
FEATURES PROVIDED COLOR CODED LEAD
RELIABILITY INDICATOR NOT ESTABLISHED
TRANSFORMER WINDING CONNECTION TYPE DELTA-WYE
MAXIMUM OPERATING TEMP200.0 DEG CELSIUS
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION FUNGUS RESISTANT AND FLAME RESISTANT AND SALT SPRAY RESISTANT AND VIBRATION RESISTANT