NSN 5930-00-329-6497
Part Details | THERMOSTATIC SWITCH
5930-00-329-6497 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).
Alternate Parts: 7015921, 70-1592-1, 50221197, 5022-11-97, 5930-00-329-6497, 00-329-6497, 5930003296497, 003296497
Supply Group (FSG) | NSN Assigned | NIIN | Item Name Code (INC) |
---|---|---|---|
59 | DEC 09, 1973 | 00-329-6497 | 00451 ( SWITCH, THERMOSTATIC ) |
REFERENCE DRAWINGS & PICTURES
CYLINDRICAL W/FLANGE

Cross Reference | NSN 5930-00-329-6497
Part Number | Cage Code | Manufacturer |
---|---|---|
70-1592-1 | 30554 | DEPARTMENT OF DEFENSE PROJECTMANAGER-MOBILE ELECTRIC POWER |
5022-11-97 | 28340 | PROTECTIVE CONTROLS INC |
Technical Data | NSN 5930-00-329-6497
Characteristic | Specifications |
---|---|
STYLE DESIGNATOR | 3 CYLINDRICAL W/FLANGE |
OVERALL LENGTH | 2.850 INCHES MINIMUM AND 2.910 INCHES MAXIMUM |
WIDTH ACROSS FLATS | 0.850 INCHES MINIMUM AND 0.910 INCHES MAXIMUM |
BODY DIAMETER | 0.540 INCHES MINIMUM AND 0.550 INCHES MAXIMUM |
BODY LENGTH | 1.750 INCHES MINIMUM AND 1.810 INCHES MAXIMUM |
NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY CLOSED, DOUBLE BREAK, MOMENTARY ACTION, WITH CONTACT ON ARM. |
CONTACT ACTION STIMULUS | INCREASE |
CONTACT ADJUSTABILITY | DEACTUATION POINT NOT ADJUSTABLE AND ACTUATION POINT NOT ADJUSTABLE |
CONTACT STIMULUS RATING | AF150.00 ACTUATION POINT NOMINAL AND AF130.00 DEACTUATION POINT NOMINAL |
OPERATING TEMP RATING | -65.0 DEG FAHRENHEIT MINIMUM AND 600.0 DEG FAHRENHEIT MAXIMUM |
MEDIA FOR WHICH DESIGNED | GAS |
TEMP SENSING ELEMENT TYPE | BULB |
CAPILLARY TUBE LENGTH | 0.970 INCHES MINIMUM AND 1.030 INCHES MAXIMUM |
TERMINAL TYPE | TAB W/SCREW |
MOUNTING METHOD | THREADED BUSHING |
FEATURES PROVIDED | HERMETICALLY SEALED CASE |