NSN 5930-01-102-2772

Part Details | THERMOSTATIC SWITCH

5930-01-102-2772 A switch that is actuated by changes in ambient temperature. Excludes CIRCUIT BREAKER; CONTROL, TEMPERATURE (as modified); FUSE (as modified); PROTECTOR, THERMAL-OVERLOAD, ELECTRICAL MOTOR; RELAY, THERMAL; and THERMOSTAT, FLOW CONTROL. See also CONTROL, TEMPERATURE (as modified) and REGULATOR, TEMPERATURE (as modified).

Alternate Parts: 24389063, 2438906-3, 171000M0D3130DEGFPORM5DEG2DEG, 17100-0-M0D3-130DEGFPORM5DEG2DEG, 171000MOD3130DEGFP5DEGFM2DEGF, 17100-0-MOD3-130DEGFP5DEGFM2DEGF, 171000MOD3130DEGFP5DEGFM2DEGF, 17100-0-MOD3-130DEGFP5DEGFM2DEGF, 5930-01-102-2772, 01-102-2772, 5930011022772, 011022772

Supply Group (FSG) NSN Assigned NIIN Item Name Code (INC)
59OCT 16, 198001-102-277200451 ( SWITCH, THERMOSTATIC )
REFERENCE DRAWINGS & PICTURES
Cross Reference | NSN 5930-01-102-2772
Part Number Cage Code Manufacturer
2438906-355972HONEYWELL INTL INCDEFENSE AVIONICS SYSTEMS
17100-0-M0D3-130DEGFPORM5DEG2DEG73168KIDDE TECHNOLOGIES INC.DBA FENWAL SAFETY SYSTEMS
17100-0-MOD3-130DEGFP5DEGFM2DEGF73168KIDDE TECHNOLOGIES INC.DBA FENWAL SAFETY SYSTEMS
17100-0-MOD3-130DEGFP5DEGFM2DEGF0KDP7KIDDE-FENWAL, INC.DBA KIDDE FIRE SYSTEM
Technical Data | NSN 5930-01-102-2772
Characteristic Specifications
OVERALL LENGTH4.656 INCHES MINIMUM AND 4.906 INCHES MAXIMUM
BODY DIAMETER0.618 INCHES MINIMUM AND 0.625 INCHES MAXIMUM
NONPILE-UP CONTACT ARRANGEMENT1 POLE, SINGLE THROW, NORMALLY CLOSED, MOMENTARY ACTION
CONTACT ACTION STIMULUS INCREASE
CONTACT ADJUSTABILITY DEACTUATION POINT ADJUSTABLE, PRESET AND ACTUATION POINT ADJUSTABLE, PRESET
CONTACT ADJUSTMENT RANGE+128.00 TO +135.00 ACTUATION POINT DEGREES FAHRENHEIT AND +128.00 TO +135.00 DEACTUATION POINT DEGREES FAHRENHEIT
CONTACT ADJUSTMENT TYPE EXTERNAL DEACTUATION POINT KNOB AND EXTERNAL ACTUATION POINT KNOB
CONTACT STIMULUS RATINGAF130.00 ACTUATION POINT NOMINAL AND AF2.00 DIFFERENTIAL POINT MINIMUM AND AF5.00 DIFFERENTIAL POINT MAXIMUM
OPERATING TEMP RATING-100.0 DEG FAHRENHEIT MINIMUM AND 400.0 DEG FAHRENHEIT MAXIMUM
MEDIA FOR WHICH DESIGNED GAS
TEMP SENSING ELEMENT TYPE INTERNAL SENSOR
TERMINAL TYPE WIRE LEAD
MOUNTING METHOD THREADED BUSHING
HAZARDOUS LOCATIONS/ENVIRONMENTAL PROTECTION DUSTPROOF AND WEATHERPROOF
END ITEM IDENTIFICATIONF/TF-15A ACFT 76301